{"product_id":"pl50-peco-lectrics-turnout-switch-module","title":"PL50 Peco Lectrics Turnout Switch Module","description":"\u003cp\u003ePL50 Peco Lectrics Turnout Switch Module.\u003c\/p\u003e  \u003cp\u003eThis carefully designed system provides all the electrical connections required for the\u003cstrong\u003e PL-26 Passing Contact Switch, \u003c\/strong\u003eand for the other switches in the Pecolectrics range (see below) and makes provision for linking the wires without the use of a soldering iron.\u003c\/p\u003e  \u003cdiv class=\"\" style11\u003e \u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e\u003cspan style=\"\" color:\u003e\u003cstrong\u003eControlling turnout operation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e \u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e1. Plug your PL-26 switch into the recess on top of the module. \u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e \u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e2. Connect each turnout motor (in the PL-10 family) to the module using wire, clamping the wire in the unit by depressing the spring-loaded green plunger. Be careful to ensure that the common return wire is plugged into the central 'green' hole. You can connect your wires to the turnout motor using the \u003cstrong\u003ePL-31 Push-On Connectors \u0026amp; Shrouds\u003c\/strong\u003e, or by using the \u003cstrong\u003ePL-34 Wiring Loom\u003c\/strong\u003e (see below). The Peco \u003cstrong\u003ePL-11 Side mounted Turnout Motor\u003c\/strong\u003e comes ready wired!\u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e \u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e3. The module comes complete with blue \u0026amp; yellow wires ready to connect to your transformer (16vAC supply).\u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e \u003c\/div\u003e  \u003cdiv class=\"\" style11\u003eAnd away you go! You have 3 switch units supplied with the PL-50, and can extend the number of units required by adding PL-51 Add-on Units to the module. Each unit simply plugs into the unit alongside, and is neatly finished off with the end caps. The whole module in turn can be secured to a surface by using screws, holes for which are incorporated within the module. Full instructions are supplied.\u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e \u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e\u003cspan style=\"\" color:\u003e\u003cstrong\u003eVersatility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e \u003c\/div\u003e  \u003cdiv class=\"\" style11\u003eThis system, whilst designed for use with Peco \u003cstrong\u003ePL-26 Passing Contact Switches\u003c\/strong\u003e for turnout operation, can also be used with the other matching switches in the Pecolectrics family. You can use the \u003cstrong\u003ePL-22 Single Pole On-Off Switch\u003c\/strong\u003e and \u003cstrong\u003ePL-23 On-On Changeover Switch\u003c\/strong\u003e with this system, but you must remember not to mix switches within one module. This is because you will most probably be using different power sources for these types of switches, and the underside connections on the switches differ from those of the PL-26. So, for example, you can have a block of PL-26 switches controlling your turnouts, another block for accessories such as signals using the PL23 Changeover Switch, and another block for the PL-22 On-Off Switch for isolating track sections.\u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e \u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e\u003cspan style=\"\" color:\u003e\u003cstrong\u003eThe Pecolectrics system - everything you need.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e \u003c\/div\u003e  \u003cdiv class=\"\" style11\u003eBy incorporating this new system with the other Pecolectrics accessories you can be up and running very easily.\u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e \u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e\n\u003cstrong\u003ePL-34 Turnout Wiring Loom -\u003c\/strong\u003e plug into your PL-10 motor, connect the loom to the Switch Module.\u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e\n\u003cstrong\u003ePL-38 Electrical Wire -\u003c\/strong\u003e available in 5 colours - to link your motors and modules, or use to extend the Wiring Loom\u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e\n\u003cstrong\u003ePL-39 Screw Terminal Blocks -\u003c\/strong\u003e safely connect wires together so you can always reach where you need to be!\u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e\n\u003cstrong\u003ePL-37 Cable Clips -\u003c\/strong\u003e secure all the wires out of the way under the baseboard by using these self adhesive clips.\u003c\/div\u003e  \u003cdiv class=\"\" style11\u003e \u003c\/div\u003e  \u003cdiv class=\"\" style11\u003eThe Pecolectrics system provides you with quality components that are easy to use and help take the worry out of getting your layout truly controlable, and without the worry of perfecting the use of a soldering iron\u003c\/div\u003e","brand":"PECO","offers":[{"title":"Default Title","offer_id":56355461693820,"sku":"PL50","price":28.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/3048\/7164\/files\/prod_28440.jpg?v=1786092793","url":"https:\/\/www.kernowmodelrailcentre.com\/products\/pl50-peco-lectrics-turnout-switch-module","provider":"Kernow Model Rail Centre","version":"1.0","type":"link"}